TRACY® Power cable (24 VDC)

TRACY® PSU

IMPORTANT NOTICE:

  • Use ONLY 24 VDC constant current PSU/Driver
  • The LED’s in this LED panel cannot be replaced.
  • The LED panel must be installed in accordance with all applicable building regulations.
  • At the end of use, the light panels must be treated as electrical scrap and disposed of in accordance with applicable regulations.

Connecting 24 VDC PSU to TRACY® light panels

Mount the PSU on an even surface in a ventilated place. 

Connect 24 VDC power cord to the PSU.



CAUTION:

Be carefull to connect power cord correctly:
POLARITY
is marked on the back side of the TRACY® Light Panels (see below):

PSU’s per 230 VAC circuit breaker

The recommended max. number of the LED PSU’s that can be connected to a Circuit Breaker/fuse type is shown as here:

Connecting PSU’s to 230 VAC Power Supply


CAUTION:

All 230 VAC wiring and connection must be installed by an electrician!

1. Before commencing any installation or maintenance work, please disconnect the power supply from the utility. Ensure that it cannot be re-connected inadvertently!

 

2. Keep proper ventilation around the unit and do not stack any object on it. Also a 10-15 cm clearance must be kept when the adjacent device is a heat source.

 

3. Mounting orientations other than standard orientation or operate under high ambient temperature may increase the internal component temperature and will require a de-rating in output current. Please refer to the specification sheet to receive the optimum mounting position and information about the de-rating curve.

 

4. Current rating of an approved primary /secondary cable should be greater than or equal to that of the unit. Please refer to its specification.

North America European Harmonized
Live and ACL Black Brown
Neutral and ACN White Blue
PE and FG (Class 1 only) Green Green/Yellow

Adjusting PSU output current (PSU without DALI)


CAUTION:

Switch on the power at the circuit breaker.

A. Turn down voltage and current (marked Vo ADJ. and Io ADJ) on the back of the PSU all the way down

B. Connect the PSU to the TRACY® light panel row

C. Adjust voltage to reach the desired current specified using a clamp meter

– if desired current level can’t be reached: go to D.

D. Adjust the current to the desired level on (Io ADJ)

Total current level is adjusted for all spots for all TRACY® panels connected to the PSU.

Support

We trust the installation of our TRACY® product went well.

For more gudelines, please visit:

PSU vendors installation Guides: 

If you need further support you can contact our customer service team at

sales@ledibond.com or call +45 7070 7855